"Known By The Companies we Keep Year after Year".....
Flow Meters ◇ Flow Switches ◇ Flow Transmitters ◇ Digital Displays
DR-1
Remote Digital Display

Remote digital displays with 4 1/2 digits for flow rate and 8 digits for totalization. Includes scaled, open collector output for remote totalizer. Numeric password protection prevents unauthorized access to menu. The easy to read menu prompts make the DR-1 so easy to program. An isolated scaled pulse output is available for hook up to a remote totalizer.
This remote digital display can be used with our 4-wire transmitter linear signal (Option W) as well as our 2-wire transmitter square root signal (Option W2, and W3) both provide 4-20mA signal Output which is proportional to flow rate, the digital display requires a 24Vdc power supply which can be purchased separately (PS-24 Power Supply) . The W2 and W3 requires a square root extraction at the receiving end.
3 1/2 or 4 1/2 Digit Rate Display (Selectable)
8 Digit Totalizer Display
16 Bit A/D Resolution
Isolated Scaled Pulse Output
Password Protection of Menu and Totalizer
Linear or Square Root Input Capable
DR-1 - Remote Digital Display
Specifications:
Power Input:
100mA, 24Vdc power supply (Not Included)
Internal Battery (Setup & totalizer memory storage only)
3 V 250mA -H Lithium (2 yr. Standby life)
Display:
Rate Display: (selectable decimal)
3.5 or 4.5 Digits (selectable), 0.35" High, display updates
once every two seconds.
Rate Descriptor: /SEC, /MIN, /HR, or Blank
Totalizer Display: (selectable decimal)
8 Digit (99999999), 0.2" High
Totalizer Descriptors: GAL, LIT, FT3, M3 or "blank"
Low Battery Error Detection: "BAT" descriptor
Under / Over range Indication: Flashing display
Environmental:
Operating Temperature
-4ºF (-20ºC) to +158ºF (70ºC)
Humidity
0-90% Noncondensing
Accuracy:
0.1% Full Scale Resolution, ± 1 Count
Temperature Drift:
50 ppm/ºC Typical
200 ppm/ºC Worst Case
Listing: CE Compliant
Inputs:
Signal Inputs:
Full Scale Range: 4 to 20 mA DC
Loop Voltage Drop: 6 Volts Maximum
Reverse Polarity Protection
Over Current Protection to 60 mA
16 Bit resolution; 1 sample every 2 seconds
Low cutoff supplied to inhibit indications at low flow rates
Reset Inputs:
Internal Pullup Resistor: 100 kΩ to ± 3 VDC
High (logic 1): Open or 3-30 VDC
Low (logic 0): Less than .5 VDC
Minimum On: 25 msec
Pulse Output:
The pulse output advances with the least significant digit of the totalizer
Type: Opto-isolated open collector transistor
Max. voltage (off state): 30 VDC
Current (on state): 5 mA @ .9 V drop, .1 mA @ .7 drop
Pulse Duration: 15 msec
Pulse Output Rate: 25 CPS max.
Pulse output divider: User selectable. ÷ 1, ÷ 10, ÷ 100 or off
Calibration & Operation:
Input Scaling: Via front keypad
Decimal Point: Via front keypad
Reset Input: Via front keypad or remote dry contact closure
Keypad: 4 tactile feedback keys
Call Toll Free: 800-356-4243 Email: sales@flo-gage.com
RCM Industries, Inc..
DR-1
Product Links


Password: Unauthorized menu changes can be prevented by entering a user selectable password (5 digit number).
Jumper: An internal jumper shunt is provided for applications requiring a sealed menu and totalizer lockout. Install the jumper to enable the lock. (see Typical Wiring, Pg. 2)